
By W. P. Jones
ISBN-10: 0080498949
ISBN-13: 9780080498942
ISBN-10: 0750650745
ISBN-13: 9780750650748
Designed for college students engineers, the 5th variation of this vintage textual content offers with basic technology and layout ideas of air-con engineering platforms. W P Jones is an stated professional within the box, and he makes use of his event as a lecturer to provide the cloth in a logical and obtainable demeanour, consistently introducing new recommendations with using labored examples. This re-creation has been absolutely up to date take into consideration the most recent advancements in criteria, laws and expertise. The booklet comprises fresh learn on construction power administration structures and the most recent refrigerants. every one bankruptcy comprises many examples, workouts and extra studying allowing the reader to extend their wisdom via extra examine. ?·Keep updated with the most recent criteria and technology?·Put conception into perform with examples and routines plus details for extra reading?·New variation comprises contemporary study on development strength administration platforms and the most recent refrigerants
Read Online or Download Air Conditioning Engineering, Fifth Edition PDF
Similar ventilation & air conditioning books
Download e-book for iPad: Energy Efficiency Manual by Donald R. Wulfinghoff
This can be the first reference, how-to consultant, and sourcebook for strength conservation. It helps you to increase potency and economize in every kind of constructions and crops, starting from person homes to advertisement constructions to giant associations and commercial crops. it really is prepared round four hundred logically grouped power conservation activities, offered in language that everybody knows.
H. Rietschel, Klaus Fitzner's Raumklimatechnik: Band 2: Raumluft- und Raumkühltechnik PDF
Das v? llig neu bearbeitete Gesamtwerk "Rietschel Raumklimatechnik" f? hrt den erstmals 1893 erschienenen "Leitfaden zum Berechnen und Entwerfen von L? ftungs- und Heizungsanlagen" fortress. Die sixteen. Auflage ist noch strukturierter und richtet sich verst? rkt auf eine integrierte Behandlung des Geb? udes und seiner klimatechnischen Anlagen aus.
Der sechste Teil dieser "Vorlesungen über Massivbau" behandelt die Brücken aus Stahlbeton und Spannbeton, deren Bauarten und Bauweisen in den letzten Jahrzehnten eine ungewöhnliche Entwicklung erfahren haben. Der Verfasser battle seit 1934 im Brückenbau tätig und hat durch viele Neuerungen zu dieser Entwicklung beigetragen, er schöpft daher aus reicher eigener praktischer Erfahrung.
This booklet offers the readers with a well timed advisor to the appliance of biomimetic rules in structure and engineering layout. because of a mixed attempt through the world over famous specialists, the biologist Werner Nachtigall and the architect Göran Pohl, the publication describes the rules which are used to check nature and expertise, and while it provides specific factors and examples displaying how biology can be utilized as a resource of idea and “translated” in construction and architectural ideas (biomimicry).
Additional info for Air Conditioning Engineering, Fifth Edition
Example text
_ 13.. t-. Q < 40 30 20 . 6132 kPa "--" -20 ~ --" 0o 20 ~ , , 40 ~ 60 ~ 80 ~ Temperature Fig. 10 The triple point of water. 100 ~ 34 Fundamental properties of air and water vapour mixtures and vapour, as changes of pressure and temperature occur. 2 Pa is defined by international agreement as the temperature at which the solid, liquid and vapour forms of water can exist together in saturated equilibrium. 15 K), respectively. We see in the figure that it is not possible for liquid water to exist at a pressure below that of the triple point.
14 Specific volume This is the volume in cubic metres of one kilogram of dry air mixed with g kilograms of water vapour. In the mixture each constituent occupies the same volume and is at the same temperature, but each exerts its own partial pressure. By Dalton's law the sum of these partial pressures is the total (barometric) pressure of the mixture. 4. 17) This equation could be used to refer to the dry air, or to the water vapour, independently if Dalton's law is accepted. In doing so, the appropriate values for the mass, particular gas constant and partial pressure of the constituent considered must be used.
It is to be noted that, when steam is mixed with dry air but the steam is not saturated, it / B' / / B At" Tc Absolute temperature (a) Pc Pb Pa Tc Wet zon Tb T~ Volume (b) Va= Vb---Vc ~ Fig. 5 (a) Saturation vapour pressure and temperature. Charles' law applies for the superheated vapour from B to C. (b) Pressure-volume diagram showing evaporation and superheating. 16 Fundamental properties o f air and water vapour mixtures is in the superheated state. 5(b) rather than by the point B. 10 Moisture content and humidity ratio Moisture content is defined as the mass of water vapour in kilograms which is associated with one kilogram of dry air in an air-water vapour mixture.
Air Conditioning Engineering, Fifth Edition by W. P. Jones
by Jason
4.4