
By -
ISBN-10: 1936504839
ISBN-13: 9781936504831
"This publication presents instruments and assistance to layout, fee, and function energetic and passive beam structures to accomplish a made up our minds indoor weather. It additionally provides examples of lively and passive beam calculations and selections"--
summary: "This ebook offers instruments and information to layout, fee, and function energetic and passive beam structures to accomplish a made up our minds indoor weather. It additionally provides examples of lively and passive beam calculations and decisions"
Read Online or Download Active and passive beam application design guide PDF
Similar ventilation & air conditioning books
Donald R. Wulfinghoff's Energy Efficiency Manual PDF
This can be the first reference, how-to consultant, and sourcebook for strength conservation. It enables you to increase potency and economize in all kinds of structures and crops, starting from person homes to advertisement constructions to massive associations and business crops. it truly is equipped round four hundred logically grouped strength conservation activities, provided in language that everybody is aware.
Das v? llig neu bearbeitete Gesamtwerk "Rietschel Raumklimatechnik" f? hrt den erstmals 1893 erschienenen "Leitfaden zum Berechnen und Entwerfen von L? ftungs- und Heizungsanlagen" citadel. Die sixteen. Auflage ist noch strukturierter und richtet sich verst? rkt auf eine integrierte Behandlung des Geb? udes und seiner klimatechnischen Anlagen aus.
Der sechste Teil dieser "Vorlesungen über Massivbau" behandelt die Brücken aus Stahlbeton und Spannbeton, deren Bauarten und Bauweisen in den letzten Jahrzehnten eine ungewöhnliche Entwicklung erfahren haben. Der Verfasser conflict seit 1934 im Brückenbau tätig und hat durch viele Neuerungen zu dieser Entwicklung beigetragen, er schöpft daher aus reicher eigener praktischer Erfahrung.
Biomimetics for Architecture & Design: Nature - Analogies - by Göran Pohl, Werner Nachtigall PDF
This booklet presents the readers with a well timed advisor to the appliance of biomimetic ideas in structure and engineering layout. because of a mixed attempt through the world over well-known professionals, the biologist Werner Nachtigall and the architect Göran Pohl, the publication describes the rules which are used to match nature and expertise, and whilst it offers designated motives and examples exhibiting how biology can be utilized as a resource of idea and “translated” in development and architectural ideas (biomimicry).
Extra resources for Active and passive beam application design guide
Sample text
In this application, the use of modulating FIGURE 10-5 Open-loop beam chilled-water system supply temperature maintained by mixing primary and secondary chilled water (three-way valve and bypass). FIGURE 10-6 Open-loop beam chilled-water system supply water temperature maintained by mixing primary and secondary chilled water (two-way valve and bypass). FIGURE 10-7 Closed-loop beam chilled-water system supply temperature maintained by regulating primary water flow in heat exchanger. 48 10 Controls valves (valve controlled) with proportional integral response is preferred.
FIGURE 8-12 Active beams installed parallel to façade (façade at top, wall at bottom). 33 Active and Passive Beam Application Design Guide FIGURE 8-13 Active beams installed perpendicular to façade (façade at top, wall at bottom). 1 is calculated in the following table. 1 ; (Rp x NP + Ra x A) Note the significant difference between the two standards in ventilation airflow requirements. 2 PRIMARY AIRFLOW REQUIRED FOR MOISTURE CONTROL The water vapour addition to the indoor air is generated by the occupants’ metabolisms.
In Figure 10-6, a two-way modulating valve and bypass are used to mix primary and return water to maintain the beam chilled-water supply temperature. 46 10 Controls FIGURE 10-3 Beam zone temperature control with demand-controlled ventilation. FIGURE 10-4 Active beams installed in a classroom. Courtesy: Swegon 47 Active and Passive Beam Application Design Guide Figure 10-7 illustrates the use of a heat exchanger and separate, closed water loop. The primary water flow in the heat exchanger is modulated to maintain the beam chilled-water supply temperature; this is used when there are several uses of the primary chilled-water circuit.
Active and passive beam application design guide by -
by William
4.2