Download e-book for kindle: 2012 ASHRAE Handbook - Heating, Ventilating, and by ASHRAE

By ASHRAE

ISBN-10: 1621980359

ISBN-13: 9781621980353

ISBN-10: 1936504251

ISBN-13: 9781936504251

This instruction manual discusses quite a few platforms and the gear (components or assemblies) they include, and describes gains and ameliorations. this knowledge is helping method designers and operators in picking out and utilizing apparatus. This version incorporates a new bankruptcy 18, Variable-Refrigerant-Flow structures, which describes those platforms, their elements, and acceptable criteria intimately, and contains a procedure layout instance and critical suggestions on expenses, controls, and security. This instruction manual is a reference for engineers operating in HVAC&R and for execs in allied fields. ASHRAE, based in 1894, is a global association of a few 50,000 individuals. ASHRAE fulfills its challenge of advancing heating, air flow, air-con, and refrigeration to serve humanity and advertise a sustainable international via examine, criteria writing, publishing, and carrying on with schooling.

Show description

Read or Download 2012 ASHRAE Handbook - Heating, Ventilating, and Air-Conditioning Systems and Equipment (I-P Edition) PDF

Best ventilation & air conditioning books

Read e-book online Energy Efficiency Manual PDF

This can be the first reference, how-to advisor, and sourcebook for power conservation. It helps you to enhance potency and economize in every kind of structures and vegetation, starting from person homes to advertisement constructions to giant associations and business vegetation. it's equipped round four hundred logically grouped power conservation activities, offered in language that everybody is familiar with.

Download e-book for iPad: Raumklimatechnik: Band 2: Raumluft- und Raumkühltechnik by H. Rietschel, Klaus Fitzner

Das v? llig neu bearbeitete Gesamtwerk "Rietschel Raumklimatechnik" f? hrt den erstmals 1893 erschienenen "Leitfaden zum Berechnen und Entwerfen von L? ftungs- und Heizungsanlagen" fortress. Die sixteen. Auflage ist noch strukturierter und richtet sich verst? rkt auf eine integrierte Behandlung des Geb? udes und seiner klimatechnischen Anlagen aus.

Read e-book online Vorlesungen über Massivbau: Sechster Teil Grundlagen des PDF

Der sechste Teil dieser "Vorlesungen über Massivbau" behandelt die Brücken aus Stahlbeton und Spannbeton, deren Bauarten und Bauweisen in den letzten Jahrzehnten eine ungewöhnliche Entwicklung erfahren haben. Der Verfasser struggle seit 1934 im Brückenbau tätig und hat durch viele Neuerungen zu dieser Entwicklung beigetragen, er schöpft daher aus reicher eigener praktischer Erfahrung.

Biomimetics for Architecture & Design: Nature - Analogies - by Göran Pohl, Werner Nachtigall PDF

This publication offers the readers with a well timed advisor to the applying of biomimetic ideas in structure and engineering layout. because of a mixed attempt via across the world well-known specialists, the biologist Werner Nachtigall and the architect Göran Pohl, the booklet describes the foundations which might be used to match nature and know-how, and while it offers distinctive factors and examples displaying how biology can be utilized as a resource of idea and “translated” in construction and architectural recommendations (biomimicry).

Additional resources for 2012 ASHRAE Handbook - Heating, Ventilating, and Air-Conditioning Systems and Equipment (I-P Edition)

Sample text

The main electrical transformer and switchgear rooms should be located as close to the incoming electrical service as practical. The main electric transformers and switchgear for the plant and the mechanical equipment switchgear panels should be in separate rooms that only authorized electricians can enter. If there is an emergency generator, it should be located considering (1) proximity to emergency electrical loads, (2) sources of combustion and cooling air, (3) fuel sources, (4) ease of properly venting exhaust gases outside, and (5) provisions for noise control.

Examples of connection strategies less costly than full renovation of a connected facility are (1) return recirculation control, to maintain a design temperature across a facility connection, or (2) separation of primary distribution supply from the secondary facility connection by a plate-and-frame heat exchanger with a control valve on the primary return controlled by the secondary supply to the facility. If the temperature split is allowed to fall, increased flow of the medium through the distribution system will be required to accomplish the same capacity.

In this instance, a preheat coil installed in the minimum outdoor airstream to warm outdoor air can produce overheating, unless it is sized so that it does not heat the air above 35 to 40°F. Assuming good mixing, a preheat coil in the mixed airstream prevents this problem. The outdoor air damper should be kept closed until room temperatures are reached during warm-up. Low-leakage dampers should be specified. A return air thermostat can terminate warm-up. When a central air-handling unit supplies both perimeter and interior spaces, supply air must be cool to handle interior zones.

Download PDF sample

2012 ASHRAE Handbook - Heating, Ventilating, and Air-Conditioning Systems and Equipment (I-P Edition) by ASHRAE


by Richard
4.3

Rated 4.21 of 5 – based on 8 votes